Converter Modbus RTU to BACnet

Converter Modbus RTU to BACnet
Product Detailed
1. Primary network protocol:BACnet MS/TP 2. Sub-network protocol: Modbus RTU 3. read/write access of up to 250 data-points. Key Specification

    PILOT  Point Expansion unit,  type HPE - BNMOD,  is for integration of Modbus RTU slave devices in to BACnet MS/TP networks. Multiple Modbus RTU devices of any mix may be connected to the HPE-BNMOD for read/write access of up to 250 data-points. All points may be individually scaled and multiple points representing Modbus registers which use multiple Words may be combined so that only one Object Instance representing the scaled multiple Word register value needs to be read up by the BMS.Application Data Primary network protocol:BACnet MS/TPSub-network protocol: Modbus RTU ----------------------------------------------------Administration points:Point 1- Diagnostic counter resetPoint 2- BACnet comms error count Point 3- Modbus comms error count Point 1000- BACnet node Point 1001- BACnet baud rate Point 1002- Modbus baud rate / config.DI- BACnet global Device Instance MM- Max MasterSV- System Vendor ID ------------------------------------------------------------------------Modbus RTU data points:250 total, point 4...253 ------------------------------------------------------------------------Supported Modbus RTU functions:01- Read (write) Coil status 02- Read Discrete Input03- Read (write) Holding Register04- Read Input Register ------------------------------------------------------------------------Comm speed selection, BACnet MS/TP:2400, 4800, 9600 (default), 19200, 38400, 76800Comm speed selection, Modbus subnet:2400, 4800, 9600 (default), 19200Modbus subnet comm configuration:7/8 data bits ¨C Odd/Even/No parity ¨C 1/2 stop bits(default ¨C 8N1)  

Payment TermsMinimum OrderLead Time / Delivery TimeSample AvailableFOB PortTarget Market(s)
T/T,  L/C
8
5 Day(s)
YES
Gaoxiong,Shenzhen,Zhuhai
Africa,  Eastern Europe,  Hong Kong/ Macao/ Taiwan,  Japan & Korea,  Latin America,  Mainland China,  Middle East,  North America,  Northern Europe,  Oceania,  South Asia,  Southeast Asia,  Western Europe

Converter Modbus RTU to BACnet



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.